Eaton 9PX 9PX8K 8kVA/7.2kW 208V Online Double Conversion Rack/Tower UPS

Eaton 9PX 9PX8K 8kVA/7.2kW 208V Online Double Conversion Rack/Tower UPS

$7,389.90
{{option.name}}: {{selected_options[option.position]}}
{{value_obj.value}}

Eaton 9PX 9PX8K 8kVA/7.2kW 208V Online Double Conversion Rack/Tower UPS Eaton 9PX 9PX8K Specifications: General Topology Double-conversion online Configuration Rack/Tower Catalog Number 9PX8K Color Black and silver Rating (VA/Watts) 8000/7200   Diagnostics Full system self test at power up UPS Bypass Yes, ships with MBP11K208 Dimensions (H x W x D, inches) 10.2 (6U) x 17.3 x 30.0 Dimensions (H x W x D, mm) 259 (6U) x 439 x 762 Weight (kg) 93 Weight (lbs) 205 Warranty 2 years Rail Kit Included 4-post rail kit and tower pedastals included Remote Emergency Power off (REPO) ROO/RPO: Rear deck emergency stop connectors (for remote on/off and power off) Contents(Ships with the following items) 9PX8KPM 8 kVA 3U UPS power module9PXEBM240RT 3U extended battery moduleMBP11K208 rear-mount maintenance bypassGigabit Network card (Network-M2)4-post rail kitUser manualQuick start guideTower pedestalsIntelligent Power Software Suite CDRS-232 serial cableUSB cableCable gland for hardwire connectionPhillips head screw driver Efficiency 94% with resistive load   Electrical Input Connection Hardwired - see manual for terminal block layout Input Cord None; hardwired Input Voltage Range Full load: 176-276V, Derating: 100-276V Nominal Voltage 208V default (200/208/220/230/240/250V) Frequency 50/60 Hz Frequency Range 60 Hz: 50–70 Hz, 50 Hz: 40–60 Hz Input Power Factor >99 Input Current Distortion <5%   Electrical Output Nominal Voltage 208V default (200/208/220/230/240/250V) Output voltage regulation ±1% steady-state Voltage THD <2% for linear loads Output Receptacles (3) NEMA L6-30R Hardwired - see manual for terminal block layout Power Factor 0.9 Transfer Time 0 ms Circuit Breaker (3) 30A for L6-30R ​ Note Configurations with more than 5 EBMs require the SC240RT super charger module   Optional Extended Battery Module 9PXEBM240RT Battery Description Sealed, lead-acid; maintenance free Maximum number of extended battery modules (EBM) Add up to 5 extended battery modules (EBM) with UPS; add up to 12 EBMs with SC240RT supercharger module Battery Management ABM technology; 3-stage charging extends battery service life by 50% and provides advance warning for battery replacement Battery Replacement Hot-swappable extended battery modules (EBMs); no internal batteries in UPS module Start On Battery Cold-start enabled; first cold start is always forbidden   Communications User Interface Graphical display. UPS status in a single view. LEDs 4 status-indicating LEDs Communication Ports RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included Communications Card Slots Gigabit Network Card (Network-M2) included Power Management Software Eaton Intelligent Power Software Suite CD (included)   Environmental & Standards RoHS Compliance Yes Surge Protection IEEE ANSI C62.41 Cat B2 Heat Dissipation (BTU) Online: 1760Battery: 2375(BTU/hr; battery full charged, resistive load) Audible Noise <45 dB at 1 meter Operating Temperature 0 to 40°C (32°F to 104°F) Safety markings CE / cULus / NOM EMC Markings IEC 62040-2:2006 Cat C2 / CISPR22 Class A / FCC part 15 Class A Storage Temperature 0 to 35°C (32°F to 95°F); without batteries: -15 to 60°C (5°F to 140°F) Relative Humidity 0 to 95% Altitude <1,000 meters for nominal power; 10% power derating every 1000 meters (up to 3000 meters)

Show More Show Less