Eaton 9PX 9PX3000GRT 3000VA/3000W 208V Online Double Conversion Rack / Tower UPS
Eaton 9PX 9PX3000GRT 3000VA/3000W 208V Online Double Conversion Rack / Tower UPS Eaton 9PX 9PX3000GRT Specifications: General Topology Double-conversion online Configuration Rack/Tower Catalog Number 9PX3000GRT Color Black and silver Rating (VA/Watts) 3000/3000 Diagnostics Full system self test at power up, and ABM test every 30 days UPS Bypass EHBPL3000R-PDU1U optional Dimensions (H x W x D, inches) 3.4 (2U) x 17.3 x 23.8 Dimensions (H x W x D, mm) 86.5 x 440 x 605 Weight (kg) 27.4 Weight (lbs) 60.4 Warranty 2 years Rail Kit Included 4-post rail kit and tower pedestals included Remote Emergency Power off (REPO) ROO/RPO: Rear deck emergency stop connectors (for remote on/off and power off) Contents(Ships with the following items) 9PX3000GRT 3 kVA UPS4-post rail kitSafety manualUser manualOutput cables (for G models)Input cables (for G models)Cable lockers (for G models)Tower pedestalsRS-232 serial cableUSB cableIntelligent Power Software Suite CDCommunication card (optional) Efficiency 93% with resistive load Electrical Input Connection (1) NEMA L6-20P Input Cord Detachable L6-20P to C19 input cord; 6 feet (1.8 meters) Input Voltage Range Full load: 176-276V, <40% load: 100-276V Nominal Voltage 208V default (200/208/220/230/240V) Frequency 50/60 Hz Frequency Range 60 Hz: 50–70 Hz, 50 Hz: 40–60 Hz Input Power Factor >.99 Input Current Distortion <5% Electrical Output Nominal Voltage 208V default (200/208/220/230/240V) Output voltage regulation ±1% steady-state Voltage THD <3% for linear loads Output Receptacles (8) IEC-320-C13 (2) IEC-320-C19 Power Cables (2) C14 to C13 jumpers Transfer Time 0 ms Optional Extended Battery Module 9PXEBM72RT Battery Description Sealed, lead-acid; maintenance free Maximum number of extended battery modules (EBM) Add up to 4 extended battery modules (EBM) Battery Management ABM technology; 3-stage charging extends battery service life by 50% and provides advance warning for battery replacement Battery Replacement Replaceable internal batteries and extended battery modules (EBMs) Start On Battery Cold-start enabled; first cold start is always forbidden Communications User Interface Graphical display. UPS status in a single view. LEDs 4 status-indicating LEDs Communication Ports RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included Power Management Software Eaton Intelligent Power Manager Environmental & Standards RoHS Compliance Yes Surge Protection IEEE ANSI C62.41 Cat B2 Heat Dissipation (BTU) Online: 619Battery: 1150(BTU/hr; battery full charged, resistive load) Audible Noise <47 dB at 1 meter Operating Temperature 0 to 40°C (32°F to 104°F) Safety markings CE / cULus / NOM EMC Markings IEC 62040-2 Class B Cat C2 / CISPR22 Class B / FCC part 15 Class B / VCCI Class B Storage Temperature 0 to 35°C (32°F to 95°F); without batteries: -15 to 55°C (5°F to 131°F) Relative Humidity 0 to 96% non-condensing Altitude 0-1500m @ 0°C - 40 °C; 1500m-3000m @ 0°C - 35 °C