RTR-574-S High Precision Data Logger

RTR-574-S High Precision Data Logger

$514.79
{{option.name}}: {{selected_options[option.position]}}
{{value_obj.value}}

The RTR-574 is a data logger designed to simultaneously measure and record Illuminance, UV intensity, temperature, and humidity.   Product RTR-574 RTR-574-H Temperature/Humidity Sensor (External) THA-3151 HHA-3151(High-Precision Type) Thermistor Polymer Resistance Platinum Resistance Electrostatic Capacitance Measurement Channels Temperature 1ch Humidity 1ch Temperature 1ch Humidity 1ch Units of Measurement °C, °F %RH °C, °F %RH Measurement Range 0 to 55 °C 10 to 95 %RH -30 to 80 °C 0 to 99 %RH Accuracy ±0.5 °C ±5 %RH [at 25 °C, 50 %RH] ±0.3 °C [0 to 50 °C) ±0.5 °C [all other temperatures] ±2.5 %RH[at 25 °C, 10 to 85 %RH] ±4.0 %RH[at 25 °C, 0 to 10 % or 85 to 99 %RH] At temperatures other than 25 °C and 0 °C, add ±0.1 %RH per degree of difference from 25. Humidity Hysteresis: ±1.5 %RH or lower(*1) Measurement Resolution 0.1 °C 1 %RH 0.1 °C 0.1 %RH Responsiveness Response Time(90%):Approx. 7 min. Response Time(90%):Approx. 7 min. Response Time(90%):Approx. 20 sec. Illuminance/UV Sensor (External) ISA-3151 Measurement Channels Illuminance: 1chUV intensity: 1ch Units of Measurement Illuminance: lx, KlxUV intensity: mW/cm2 Measurement Range Illuminance: 0 lx to 130 KlxUV Intensity: 0 to 30 mW/cm2 Units of Cumulative Measurement Cumulative Illuminance: lxh, Klxh, MlxhCumulative amount of UV Light: mW/cm2, W/cm2 Display Range of Cumulative Measurement Illuminance: 0 lxh to 90 MlxhUV Intensity: 0 mW to 62 W/cm2h Accuracy Illuminance: 10 lx to 100 Klx"¢__ ±5 % [at 25 °C, 50 %RH] UV Intensity: 0.1 to 30 mW/cm2"¢__ ±5 % [at 25 °C, 50 %RH] (*2) Relative Spectral Response Illuminance: Approximated to the CIE standard response function V (ÌÇÌö )UV Intensity: 260 to 400 nm Measurement Resolution Illuminance: Minimum of 0.01 lxUV Intensity: Minimum of 0.001 mW/cm2 Responsiveness Response Time(90%):3 sec. (at recording interval of 1 sec.)6 sec. (at other intervals) Logging Capacity 8,000 data sets (One data set consists of readings for all channels in that type of unit.) Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. Recording Mode (*3) Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) LCD Display Items Measurements, Battery Life Warning, etc.̴?_«Measurements: Illuminance / UV Intensity / Temperature / Humidity / Cumulative Illuminance / Cumulative amount of UV Light̴?_«Display Pattern: Alternating or Fixed display̴?_«Display Digits: Up to 4 digits Communication Interfaces Wireless Communication (Short Range Radio Communication)̴?_«FCC Part15 Section247 / IC RSS-210 (Frequency Range: 902 to 928MHz, RF Power: 7mW)̴?_«ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz, RF Power: 5mW)USB CommunicationSerial Communication (RS-232C)(*4) Wireless Transmission Range Approx. 150 meters (500 ft) if direct and unobstructed Power AA Alkaline Battery (LR6) x 1 Battery Life (*5) Approx. 4 months Dimensions H 55 mm x W 78 mm x D 18 mm(excluding protrusions)Antenna Length: 60 mm Weight About 68 g (including battery, excluding sensor) Operating Environment Temperature: -10 to 60 °C Humidity: 90 %RH or less (no condensation) Accessories AA alkaline battery (LR6), USB Communication Cable (US-15C), Illuminance/UV Sensor (ISA-3151), Temperature/Humidity Sensor (THA-3151 or HHA-3151), Software (CD-ROM), User's Manual Set (Warranty Included) Compatible Base Units RTR-500, RTR-500NW/500AW, RTR-500DC *1 When used in environments where temperature and humidity are over the values of 50 °C 75%, 60 °C 50%, 70 °C 35%, and 80 °C 25%, sensor hysteresis may fluctuate by values greater than ±1.5%RH. Under certain circumstances, it may take some time to return to normal measurement capability. *2 Compared to the value measured by the T&D standard sensor for calibration under our calibration light source. *3 Only "Endless" is available when using RTR-500W for Windows. *4 For communication with the Data Collector RTR-500DC (Note: Optional serial communication cable TR-6C10 is required. *5 Battery life varies depending upon the ambient temperature in which it is used, the recording interval, the frequency of communication, and the battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life.

Show More Show Less

Price History

$514.79 (+$46.50)