
Load Suppressor
The Nolatron Load Suppressor contains a metal-oxide varistor (MOV) that limits the level of transient voltage. It also contains an R/C snubber network that limits the electromagnetic interference (EMI) of the transient. This greatly reduces the damage that transients can cause to relay contacts and also reduces the influence they have on electronic equipment. SPECIFICATIONS:Max. Applied Voltage: 250 VACMax. Transient Energy: 30 joules @ 1000 uS.Max. Surge Current: 4000 AMPS @ 20 uS.Typ. Power Cosumption: 1.2 Watts @ rated voltageMax. Temperature: Up to 48°C (120°F) INSTALLATION1. Trim the wire to desired length.2. Strip the insulation of the leads and attach them to both power lines of the load. The suppressor will then be in parallel with the load.3. Mount the module to machine using the two flanges. The module may also be mounted to a wiring harness by running a wire-tie through the flanges and then around a