Fluke 725/APAC/EDC Multifunction Process Calibrator

Fluke 725/APAC/EDC Multifunction Process Calibrator

$7,012.00
{{option.name}}: {{selected_options[option.position]}}
{{value_obj.value}}

The FLUKE725/APAC/EDC (Prev. Fluke-725) Multifunction Process Calibrator is simply powerful! (item no. 5131140) With the FLUKE725/APAC/EDC Multifunction Process Calibrator you can easily source and measure almost any process parameter and test almost any process device. Measure and source mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure, using optional pressure modules. From the moment you pick it up, the FLUKE725/APAC/EDC is ready to perform as a powerful, yet easy-to-use field calibrator. Its simple controls, without menus, make operation easy. Features Powerful, easy-to-use field calibrator Measures volts, mA, pressure, RTDs, thermocouples, frequency, and ohms to test sensors and transmitters Sources/simulates volts dc, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters Measures/sources pressure using any of 50 Fluke 750P Pressure Modules Easy to read measure/source screen displays input and output simultaneously Other useful features: Powers transmitters during test using loop supply with simultaneous mA measurement Handles fast pulsed RTD transmitters and PLCs, with pulses as short as 10 ms Provides a backlit display to provide better visibility in poor light Features small, streamlined shape, and rugged, reliable design that stands up to field use Sources mA with simultaneous pressure measurement to conduct valve and I/P tests Supports flow meter testing with frequency and CPM functions Performs fast linearity tests with auto-step and auto-ramp features For more precision, pulse sourcing, totalizing and more consider the Fluke 726 Precision Multifunction Calibrator. If you need an intrinsically-safe rated calibrator, consider the Fluke 725Ex Intrinsically Safe Multifunction Process Calibrator. For documenting and HART communication built into your calibrator, consider the Fluke 754 Documenting Process Calibrator with HART. Models: FLUKE725/APAC/EDC Multifunction Process Calibrator FLUKE725/APAC/EDC FLUKE725/APAC/EDC Multifunction Process Calibrator Includes: One set of AC72 alligator clips One set of stackable test leads One set of TL 75 testleads User manuals NIST- traceable calibration report and data Specifications: FLUKE725/APAC/EDC Multifunction Process Calibrator Measurement Accuracy Voltage DC 30.000 V 0.02% + 2 counts (upper display) 30.000 V 0.02% + 2 counts (lower display) 100.00 mV 0.02% + 2 counts -10.00 mV to 75.00 mV 0.025% + 1 count (via TC connector) Current DC 24.000 mA 0.02% + 2 counts Resistance 0.0 to 400.0 Ω 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire) 401 to 1500 Ω 0.5 Ω (4-wire), 1 Ω (2- and 3-wire) 1500 to 3200 Ω 1 Ω (4-wire), 1.5 Ω (2- and 3-wire) Frequency 2.0 to 1000.0 CPM 0.05% + 1 count 1.0 to 1100.0 Hz 0.05% + 1 count 1.00 to 10.00 kHz 0.05% + 1 count Sensitivity 1 V peak-to-peak-minimum Pressure Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure. Source Accuracy Voltage DC 100.00 mV 0.02% + 2 counts 10.000 V 0.02% + 2 counts -10.00 mV to 75.00 mV 0.025% + 1 count (via TC connector) Current DC 24.000 mA (source) 0.02% + 2 counts 24.000 mA (simulate) 0.02% + 2 counts Resistance 15.0 to 400.0 Ω 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA) 401 to 1500 Ω 0.5 Ω (excitation current 0.05 to 0.8 mA) 1500 to 3200 Ω 1 Ω (excitation current 0.05 to 0.4 mA) Frequency 2.0 to 1000.0 CPM 0.05% 1.0 to 1100.0 Hz 0.05% 1.00 to 10.00 kHz 0.25% Waveform 5 V p-p squarewave, -0.1 V offset RTDs and Thermocouples Measure accuracy NI-120 0.2°C PT-100 (385) 0.33°C PT-100 (393) 0.3°C PT-100 (JIS) 0.3°C PT-200 (385) 0.2°C PT-500 (385) 0.3°C PT-1000 (385) 0.2°C Resolution 0.1°C J 0.7°C K 0.8°C T 0.8°C E 0.7°C R 1.8°C S 1.5°C B 1.4°C L 0.7°C U 0.75°C N 0.9°C Resolution J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F XK 0.6°C BP 1.2°C Source accuracy NI-120 0.2°C PT-100 (385) 0.33°C PT-100 (393) 0.3°C PT-100 (JIS) 0.3°C PT-200 (385) 0.2°C PT-500 (385) 0.3°C PT-1000 (385) 0.2°C Resolution 0.1°C Accuracy stated for 4-wire measurement. J 0.7°C K 0.8°C T 0.8°C E 0.7°C R 1.4°C S 1.5°C B 1.4°C L 0.7°C U 0.75°C N 0.9°C Resolution J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C XK 0.6°C BP 1.2°C Specifications Ramp functions Source functions Voltage, current, resistance, frequency, temperature Ramps Slow ramp, Fast ramp, 25% step-ramp Loop power function Voltage 24 V Accuracy 10% Maximum current 22 mA, short circuit protected Step functions Source functions Voltage, current, resistance, frequency, temperature Steps 25% of range, 100% of range Environmental Specifications Operating temperature -10°C to +55°C Storage temperature -20°C to 71°C Operating altitude 3000 m Safety Specifications Agency approvals EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992 Mechanical and General Specifications Size 130 x 236 x 61 mm Weight 0.65 kg Batteries 4 AA alkaline batteries Battery replacement Separate battery compartment, accessable without breaking calibration seal Side port connections Pressure module connector, also used for remote real-time programming Resources: FLUKE725/APAC/EDC Multifunction Process Calibrator Manuals 725 | Users manual 725 | Users manual supplement 718,719,724,725, 726 | Safety sheet 724/725/726 | Calibration manual 725 | Statement of memory volatility Data Sheets 725 Multifunction Calibrator Brochures Pressure Calibration APPLICATIONS AND SOLUTIONS

Show More Show Less

Price History

$7,012 (+$204.23)