
Fluke 87V MAX True-rms Digital Multimeter
Product overview The 87V MAX contains all the trusted features of the most popular DMM used today, the Fluke 87V, plus much more. Withstands drops up to 4-meters (13 feet) Fluke’s most rugged digital multimeter. The 87V MAX is built with an industrial strength case and a removable holster. The holster doubles as a test probe holder for one-handed operation. IP67 rated Fully waterproof and dust proof, to work reliably in all the places that you need to work. Withstands heat and cold The meter has an extended operating temperature range of -40 °C (for up to 20 minutes) to +55 °C. Other product highlights True-rms ac voltage and current for accurate measurements on non-linear signals Measure up to 1000 V ac and dc Measure up to 10 A (20 A for 30 seconds) Frequency to 200 kHz Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument Min/Max/Average recording, plus 250 μs Peak min-max to capture variations automatically Unique function for accurate voltage and frequency measurements on variable frequency motor drives (VFDs) and other electrically noisy equipment Large display digits, 2-level bright white backlight and backlit keypad buttons for increased visibility Hi resolution 19,999 count display mode Long battery life (800 hours) Features Withstands drops up to 4-meters (13 feet) with industrial strength casing and holster Waterproof, dustproof IP67 case for the most extreme work sites Premium TL175 TwistGuard™ test leads Double the battery life of the 87V (up to 800 hours); backlit keys for dark environments Comparison – 87V MAX and 87V 87V MAX 87 V IP Rating IP 67 IP 30 Battery life 800 hours 400 hours Drop test 4 meters 3 meters Backlit keypad Yes No TwistGuard™ test leads Yes No True-rms readings ac ac Basic dc accuracy 0.05% 0.05% Voltage ac/dc 1000 V 1000 V Current ac/dc 10 A 10 A Resistance 50 MΩ 50 MΩ EN61010-1 CAT III 1000 V 1000 V EN61010-1 CAT IV 600 V 600 V Warranty (years) Limited lifetime Limited lifetime Specifications: Fluke 87V MAX True-rms Digital Multimeter Electrical Specifications DC Voltage Range 0.1 mV to 1000 V Accuracy ±(0.05% + 1) Maximum resolution 0.1 mV AC Voltage Range 0.1 mV to 1000 V Accuracy ±(0.7% + 4) true-rms AC bandwidth 20 kHz with low pass filter; 3 dB @ 1 kHz Maximum resolution 0.1 mV DC Current Range 0.1 μA to 10 A(20 A for 30 seconds maximum) Amps accuracy ±(0.2% + 2) Maximum resolution 0.1 µA AC Current Range 0.1 μA to 10 A(20 A for 30 seconds maximum) Amps accuracy ±(1.0% + 2) true-rms Maximum resolution 0.1 µA Resistance Range 0.1 Ω to 50 MΩ Accuracy ±(0.2% + 1) Maximum resolution 0.1 Ω Capacitance Range 0.01 nF to 9999 μF Accuracy ±(1% + 2) Maximum resolution 0.01 nF Frequency Range 0.5 Hz to 199.99 kHz Accuracy ±(0.005% + 1) Maximum resolution 0.01 Hz Duty cycle Maximum duty cycle 99.9% Accuracy ±(0.2% per kHz + 0.1%) Maximum resolution 0.1% Temperature measurement range –200.0 °C to 1090 °C–328.0 °F to 1994.0 °Fexcluding probe 80 BK temperature probe –40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater–40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater Conductance Maximum conductance 60.00 nS Accuracy ±(1.0% + 10) Maximum resolution 0.01 nS Diode test Range 2 V Resolution 0.001V Accuracy ±(1% + 1) Diagnostics and data storage Peak Min/Max 250 μS Min/Max/Avg Yes Reading hold/Auto (Touch) Hold Yes Relative reference Yes Display Digital 6000 counts updates 4/second19,999 counts in high–resolution mode Analog bar graph 32 segments, updates 40/second Backlight Two level Low pass filter (VFD measurements) Yes Input Alert™ Yes Safety Specifications Safety rating IEC61010-1: Pollution Degree 2IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V Agency approvals CE, CSA Mechanical and General Specifications IP rating IEC 60529: IP67 Power Three AA batteries. 800 hours typical, without backlight Size 6.0 x 10.1 x 21.5 cm (with holster) Weight 698.5 g (with holster) Warranty Limited lifetime Environmental Specifications Operating temperature -15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C Storage temperature -40 °C to + 60 °C Humidity (without condensation) 0% – 90% (0 °C – 35 °C)0% – 70% (35 °C – 55 °C) Operating altitude 2000 m Includes: TL175 TwistGuard® test leads AC175 Alligator clips 80BK-A temperature probe Removable holster with test lead storage Three AA batteries (installed) Manuals 80 Series V | Users manual 80 Series V | Users manual supplement 80 Series V | Calibration manual 80 Series V | Calibration manual supplement 80 Series V | Getting started 80 Series V | Getting started supplement 80 Series V | Safety sheet 80 Series V, 83 V, 85 V, 87 V | Quick reference guide 83, 87, 88 Series V | Statement of memory volatility 88 V | Quick reference guide Data Sheet 87V Detailed Specification Sheet