Fluke 5626 Secondary Standard PRTs, 100 OHM 1/4IN DIA X 15IN

Fluke 5626 Secondary Standard PRTs, 100 OHM 1/4IN DIA X 15IN

$6,510.00
{{option.name}}: {{selected_options[option.position]}}
{{value_obj.value}}

(item no. 1653929, 1653934, 1653952, 1653965, 1653976, 1653983, 1653990, 1654000) PRODUCT OVERVIEW High-temperature secondary standards Range to 661°C Meets all ITS-90 requirements for resistance ratios Rtp drift < 20 mK after 500 hours at 661°C Calibrated accuracy of ± 0.006 °C at 0 °C Fluke Calibration's high-temp secondary standards fill the gap between affordable, but temperature-limited secondary PRTs (platinum resistance thermometers) and more expensive, highly accurate SPRTs (standard platinum resistance thermometers). If you’re using block calibrators, furnaces, or temperature points above normal PRT (platinum resistance thermometer) temperatures (420 °C), then these two PRTs are for you. The Fluke 5626 is nominally 100 Ω and the 5628 (formerly Hart Scientific) is nominally 25.5 Ω. Both instruments have a temperature range of –200 °C to 661 °C. They make great working or check standards for calibration work up to the aluminum point. Using a regular PRT at temperatures above 500 °C exposes the platinum to contamination. If the PRT is used as a reference or calibration standard, contamination is a major problem. SPRTs (standard platinum resistance thermometers), which are more expensive and delicate, can handle the higher temperatures, but with greater risk to the instrument due to shock, contamination, or mishandling. The 5626 and 5628 are designed to reduce the contamination risk through the use of internal protection while not impairing performance. In addition to the right measurement performance and durability, a PRT for secondary applications should be priced affordably. Fluke Calibration’s new PRTs are inexpensive and come with an accredited calibration. The calibration comes complete with ITS-90 constants and a resistance-versus-temperature table. Check the temperature range, check the stability, check the price! Who else gives you this much quality, performance, and value for your money? No one!   SPECIFICATIONS Temperature Range  –200 °C to 661 °C  Handle Temp.  0 °C to 80 °C  RTPW  5626: 100 Ω (± 1 Ω)5628: 25.5 Ω (± 0.5 Ω)  Resistance Ratio W(Ga) W(302.9146K) ≥ 1.11807α ≥ 0.003925 Calibrated Accuracy†(k=2)  ± 0.006 °C at –200 °C± 0.006 °C at 0 °C± 0.015 °C at 420 °C± 0.022 °C at 661 °C  Stability  5626: ± 0.003 °C5628: ± 0.002 °C  Long-Term Drift (k=2)  5626:  < 0.006 °C/100 hours at 661 °C5628: < 0.004 °C/100 hours at 661 °C  Immersion  At least 12.7 cm (5 in) recommended  Sheath  Inconel™ 600  Lead Wires  4-wire Super-Flex PVC, 22 AGW  Termination  Gold-plated spade lugs, or specify  Size  6.35 mm dia. x 305 mm,  381 mm,  or 508 mm (0.25 x 12, 15, or 20 in) standard, custom lengths available  Calibration  Accredited calibrations from Fluke Calibration †Includes calibration and 100 hr drift Model Specifications  5626-15-B: Measures 15 x 0.25in and comes equipped with bare wire connections. 5626-15-D: Measures 15 x 0.25in and comes equipped with 5-pin DIN connections. 5626-15-G: Measures 15 x 0.25in and comes equipped with gold pin connections. 5626-15-I: Measures 15 x 0.25in and comes equipped with INFO-CON connections for 1521 and 1522 models. 5626-15-J: Measures 15 x 0.25in and comes equipped with banana plug connections.  5626-15-L: Measures 15 x 0.25in and comes equipped with mini-spade lug connections.  5626-15-M: Measures 15 x 0.25in and comes equipped with mini banana plug connections.  5626-15-S: Measures 15 x 0.25in and comes equipped with spade lug connections.   

Show More Show Less

Price History

$6,510 (+$338.80)