
SHEL LAB SRI Peltier Cooled Incubators
Overview Innovative peltier cooling technology, eliminates the need for a refrigeration compressor in the peltier cooled series. These units use 78% less power than alternative models and reduce room air conditioning loads by 75%. They also include 75 pound capacity shelves, which eliminates sagging. These incubators meet APHA specifications for Biochemical Oxygen Demand (B.O.D.) and include a mechanical convection system to ensure even air distribution, digital temperature set controller, over temperature limit control, and a digital temperature display. Features: Microprocessor Control Precise Temperature Control Superior Uniformity Independent Overtemperature Thermostat Over Temperature Alarm Temperature Uniformity +/- 0.5ºC at 20ºC Temperature Range 15°C to 40°C at 20°C Ambient P.I.D. Temperature_Control LED Display of Setpoint and Chamber Temperature High Limit Thermostat Interior Electrical Outlet Fan Assisted/Forced-Air Circulation 24 Month Limited Warranty PLEASE NOTE: SRI Peltier Cooled Incubators are manufactured at the time the order is placed. A three week lead time should be expected. Key Attributes Cu ft. 6.5, 19.3 Max Temp 40°C at 20°C Ambient Min Temp 15°C at 20°C Ambient Temp Uniformity ± 0.5°C Interior Outlets Yes Alarms Yes Datalogging Capable No Warranty (years) 2 Site Floor Weight (lbs) 245, 405 Manufacturer Specifications BOD Incubators Details SRI6P SRI20P Under Counter Large Capacity Exterior Dimensions (wxdxh) Inches 30.0 x 31.5 x 33.5 30.0 x 31.5 x 69.5 Chamber Dimensions (wxdxh) Inches 25.5 x 24.0 x 18.5 25.5 x 24.0 x 54.5 Incubator Chamber Capacity cu ft 6.5 19.3 L 185 546 Interior Outlet Number 120V -1 / 230V-2 120V-1 / 230V -2 Bottle Capacity Number 120 300 Number of Shelves Included 2 5 FAQ Do the SRI Peltier Cooled Incubators have internal lights? What kind of lighting is used? Yes, there are internal lights which activate upon door opening. All Sheldon Manufacturing Peltier-cooled incubators use only low-heat LED lights. How does the electricity usage of the SRI Peltier Cooled Incubators compare to traditional compressor-cooled incubators? Peltier cooling is much more efficient. Peltier cooled incubators will consume significantly less electricity and produce less waste heat than traditional refrigerated incubators. How reliable is a peltier-cooled incubator? What is the expected lifespan? Peltier-cooled incubators generally have somewhat longer lives than traditional, compressor-cooled incubators. The mean time between failure for thermoelectric Peltier cooling plates have been estimated to have between 100,000 and 200,000 hours mean time between failures, which would equate to approximately 11.5 - 23 years of continuous use. Furthermore, the thermoelectric cooling and heating device is easier and less expensive to replace than a compressor, and does not require a refrigeration technician to do so.