
FLUKE-1587 FC/WWG Insulation Multimeter 0.01 megaohm to 2 gigohm, CAT III 1000V/CAT IV 600V, Battery, Digital
Insulation Multimeter, Backlit Digital Display Yes, Bluetooth Compatible Yes, CAT Safety Rating CAT III 1000V, CAT IV 600V, Calibration Certificate None, Capacitance Auto Discharge Yes, Display Type Digital, Dustproof No, Greater Than 30V Warning Yes, Includes Alligator Clip, Hard Case, K-Type Thermocouple, Remote Probe, Test Leads, Insulation Limit Alarm No, Maximum Insulation Resistance 2 gigohm, Minimum Insulation Resistance 0.01 megaohm, PI/DAR Testing Yes Max. AC Volts 1,000 Max. DC Volts 1,000 Max. AC Amps 400 mA Max. DC Amps 400 mA Resistance Range 0 to 50 megohm Interface Bluetooth Auto Power Off Yes Display Digital LCD with Backlit Calibration Certificate None Includes Alligator Clip, Hard Case, K-Type Thermocouple, Remote Probe, Test Leads Insulation Resistance Range 0.01 megaohm to 2 gigohm Temp. Range -40 Degrees to 998 Degrees F Power Source Battery Features Insulation Resistance Test Results Wirelessly with Your Smartphone Data Logging 6000 Auto Ranging Yes Output Test Voltage 50/100/250/500/1000V DC Live Circuit Detection Greater Than 30V Capacitance Range 1000 nF to 9999 uF Diode Test Yes Safety Rating CAT III 1000V, CAT IV 600V Standards IEC 61326-1, IEC 61326-2-2 CISPR 11 Meter Type Insulation Multimeter Product Type Tester Only Display Type Digital Parameters Measured Insulation Resistance Communication Protocol Bluetooth CAT Safety Rating CAT III 1000V, CAT IV 600V Megohmmeter Features Bluetooth-Compatible Number of Digits 5 Number of Records Stored 6,000 Operating Voltage 1,000V Bluetooth Compatible Yes Includes Batteries Yes IP Rating IP40 Capacitance Auto Discharge Yes Maximum Operating Temperature 998 Degrees F PI/DAR Testing Yes Dustproof No Leakage Current Range 1.0 mA Minimum AC Current Measured 0.1 mA Testing Functions Insulation Minimum AC Voltage Measured 600 mV Maximum AC Current Measured 400 mA Data Logger Yes Input Impedance 10 megaohm Battery Chemistry Alkaline Maximum Insulation Resistance 2 gigohm Greater Than 30V Warning Yes Number of Batteries Required 4 Pass/Fail Selection Limits No Insulation Resistance Resolution 0.01 megaohm to 2 gigaohm Timed Ramp Voltage Test Yes USB Data Download Included No Test Voltage 1,000V DC, 100V DC, 250V DC, 500V DC, 50V DC Remote Test Probe Included Yes Backlit Digital Display Yes Minimum Insulation Resistance 0.01 megaohm Test Current 400 mA Insulation Limit Alarm No Minimum Capacitance Measured 1,000 nF Minimum DC Voltage Measured 6 V Maximum Capacitance Measured 9,999 nF Maximum DC Voltage Measured 1,000 V Minimum Operating Temperature -40 Degrees F Maximum DC Current Measured 400 mA Waterproof No Maximum AC Voltage Measured 1,000 V Resistance Accuracy +/-3.00% +5 digits Display Screen Type LCD Live Circuit Voltage Greater Than30V