Pipeline Resistance Calculation for RO Piping System In principle, to determine the optimal pipe diameter, different flow velocities can be used as calculation scenarios to find the most economical and reasonable velocity or pipe size. For pipelines within a workshop, the flow rate can be empirically selected within the economical range, then the pipe diameter is calculated using the mass conservation formula and rounded according to pipeline standards. Flow resistance is mainly composed of two parts: Straight pipe resistance, which causes mechanical energy loss due to flow friction. Local resistance, caused by elbows, valves, and other fittings. In most cases, straight pipe resistance is negligible compared to local resistance. In this design system, the target product water output is 0.5 t/h. Reverse Osmosis Membrane Selection: The selected membrane model is 4040, with a unit output capacity of 0.25 t/h.Thus, two membranes are sufficient to meet the design capacity. To ensure