
CONTEC TLC6000 ECG Monitor
Introduction This funky ECG system rocks a 12-lead layout that follows global standards to capture and examine ECG waveforms for a nonstop 24-hour sesh. The included PC software kicks it up a notch with in-depth analysis. Perfect for medical peeps and community cats alike.Specifications1) This product features a 12-lead system that complies with international standards and provides 24-hour continuous recording of ECG waveforms. 2) Ensure accurate detection of QRS waveforms for all selected channels with the option to designate a main analysis channel for 12-lead synchronization and precise waveform assessment, without any distortion. 3) With over 10 templates, including atrial and ventricular premature beats, long intervals, and atrial fibrillation, as well as customizable modules, this system can accurately identify a wide range of pathologic waveforms. 4) Enhance atrial fibrillation examination with this software's diverse AUTO/manual analysis choices for a more accurate diagnosis. Physicians have the option to assess the entire record or select segments for analysis. 5) Utilize the robust pacemaker analysis feature to examine a variety of pacemakers, including AAI, VVI, DDD, and more. 6) The fast review analysis function allows for the review of single or full-lead ECGs within any time period. 7) Featuring analysis functions for 5-minute, 1-hour, and overall heart rate variability, this product offers comprehensive ECG/EKG monitoring for up to 24 hours. 8) One-key print, convenient and fast to print the reports. 9) The HRT analysis function can predict the risk of death in patients with myocardial infarction. 10) T-wave alternation is a crucial factor in predicting both malignant arrhythmia and sudden cardiac death.11) With the ability to analyze QTD (QT dispersion), VCG (vector cardiogram), VLP (ventricular late potential), and TVCG (time vector cardiogram), this product provides a comprehensive and valuable analysis report.Performance 1)Lead: standard 12-lead 2)Power supply: one “AAA” alkaline battery 3)Interface: USB2.0 4)Input impedance: ≥10MΩ 5)CMR: ≥60dB 6)Gain accuracy: At all possible gain settings, the maximum amplitude error of the output is ±10% 7)Gain stability: One minute after energizing the device, the gain change in stable ambient conditions shall not exceed 3% over a 24h period. 8)System noise: ≤50µVp-p 9)Multichannel crosstalk: ≤0.2mV 10)Frequency response: The amplitude response to sinusoidal signals within the frequency range 0.05Hz to 40Hz shall be between the +3dB to -3dB of the response at 5 Hz. 11)Minimum measure signal: 50 µV 12)Timing accuracy: the overall error during 24h shall not exceed 30s.Accessories Lead cable (1 set) ECG electrode (1 bag) USB cable(1) Bag(1) User manual(1)Physical characteristicsRecorder dimension: 81mm(L) × 60mm(W) × 22mm(H) Weight: about 61.5g(without batteries)