IPS-HS1 Controller
TECHNICAL PARAMETERS Model IPS-HS1 For Motor Qty 1-4 PCS Input Voltage DC24-32V Working Temperature -20℃~+40℃ Output Voltage DC24V Storage Temperature -20℃~+90℃ Power 320W Max 10A Working Humidity 20%-90% Receiver Rs485/RF433/IO Other Functions Location memory and display Controller Type Hall 6-Wire Control Key Mode Press Continuous Optional Functions 2.5 meter spring wire manual controller / Sensor Switch / PLC Note: You need to consult us before you can modify the controller. Please do not modify randomly, it will cause the electric actuator damage. You Need to record every value (n01-n 12) before modification 1. Press the'S, 1, 2, 3'buttons in sequence to enter the settings2. RST malfunction occurs, please press the 'V' button to reset3. To use sensor control, please press'S, 3, 2, 1'to enter the settings4. After setting the parameters, please press 'S' for 3 seconds to save DIMENSIONS WIRING INSTRUCTION WIRING INSTRUCTION Error code'rst'. Please press the'V'key