Eaton 9355 10kVA 9kW 600/208V 32-Battery w/Isolation Transformer 3-Phase UPS
Eaton 9355 10kVA 9kW 600/208V 32-Battery w/Isolation Transformer 3-Phase UPS The Eaton 9355 UPS provides premium double-conversion backup power and scalable battery runtimes for IT and electrical engineering infrastructure in corporate, healthcare, banking and industrial applications. Packing maximum battery runtime into a very small footprint, the 9355 UPS is a complete three-phase power protection solution. The 9355 can be equipped with an integrated, customizable power distribution module that includes a maintenance bypass switch. Power Ratings (kVA/Watts) 10 kVA/9 kW and 15 kVA/13.5 kW at 0.9 power factor Topology Double conversion Electrical Input Nominal input voltage 208V/120V or 220V/127V three-phase 400V models also available Input voltage range -15%, +10% from nominal at 100% load without depleting battery Operating frequency 50/60 Hz (45 to 65 Hz) Input power factor >0.99 typical, >0.96 frequency converter Input current distortion 5% THD Electrical Output Nominal output voltage 208/120, 220/127 Vac Output voltage regulation ±1% static; ±5% dynamic at 100% resistive load change, <1 ms response time Efficiency 91%, typical Heat dissipation (BTU/hr) 10 kVA models:3,798 @ 208V and 220V input6,294 @ 480V and 600V (with input isolation transformer)15 kVA models:5,122 @ 208V and 220V input8,134 @ 480V and 600V (with input isolation transformer) Battery Battery type 9 Ah, sealed, lead-acid, maintenance-free Battery runtime See battery backup time chart Battery management ABM technology Battery replacement Field-replaceable Charger Default is 3.4A per battery string. Charger current is configurable from 0.5A to 25A per string with an overall maximum of 34A (limited by input current) Start-on-battery Allows start of UPS without utility input General Diagnostics Full system self-test at startup UPS bypass Automatic on overload or UPS failure Parallel for redundancy Yes, using Powerware Hot Sync technology and capacity Dimensions and weights See model selection table Overload (normal operation) 150% for 5 sec / 125% for 1 min (online),110% for 10 min Communications LCD display Graphical LCD with blue backlight LEDs (4) LEDs for notice and alarm Audible alarms Yes Communication ports (1) RS-232, (1) relay contact, (1) REPO,(2) environmental input Communication slots (2) X-Slot communication bays Power management software Bundled Software Suite CD Environmental Operating temperature 50–104ºF (10–40ºC), 45ºC with 7.5% derating; Optimal battery performance: 77ºF (25ºC) Storage temperature 32–77ºF (0–25ºC); Recommended battery storage: 59–77ºF (15–25ºC) Relative humidity 0–95%, non-condensing Audible noise <56 dBA at 1 meter (noiseless room) typical Altitude 9,843 ft. (3000m) without derating Certifications Safety certifications UL1778 5th Edition, CSA C22.2 No. 107.3-14 EMC compliance 47 CFR Part 15/ICES-003 Class A Quality ISO 9001:2015, ISO 14001:2004 Surge ANSI C62.41 Category B3, IEC 61000-4-5 Markings cULus 1. Due to continuous product improvements, program specifications are subject to change without notice. Model Selection Table PowerRating (kVA/kW)1 Description Input/OutputVoltage Part Number2 Base Runtime Dimensions(HxWxD, in.) Weight(lb.)3 10 / 9 2-high w/32 battery 208/208 KA1011100000010 8 32.2 x 12.0 x 33.5 373.0 10 / 9 3-high w/64 battery 208/208 KA1012100000010 22 47.8 x 12.0 x 33.5 609.0 10 / 9 2-high w/32 battery 220/2204 KA1011200000010 8 32.2 x 12.0 x 33.5 373.0 10 / 9 3-high w/64 battery 220/2204 KA1012200000010 22 47.8 x 12.0 x 33.5 609.0 10 / 9 3-high w/32 battery and input isolation transformer 480/208 KA1013400000010 8 47.8 x 12.0 x 33.5 577.0 10 / 9 3-high w/32 battery and input isolation transformer 600/208 KA1013600000010 8 47.8 x 12.0 x 33.5 577.0 15 / 13.5 2-high w/32 battery 208/208 KA1511100000010 4 32.2 x 12.0 x 33.5 373.0 15 / 13.5 3-high w/64 battery 208/208 KA1512100000010 13 47.8 x 12.0 x 33.5 609.0 15 / 13.5 2-high w/32 battery 220/2204 KA1511200000010 4 32.2 x 12.0 x 33.5 373.0 15 / 13.5 3-high w/64 battery 220/2204 KA1512200000010 13 47.8 x 12.0 x 33.5 609.0 15 / 13.5 3-high w/32 battery and input isolation transformer 480/208 KA1513400000010 4 47.8 x 12.0 x 33.5 577.0 15 / 13.5 3-high w/32 battery and input isolation transformer 600/208 KA1513600000010 4 47.8 x 12.0 x 33.5 577.0