Eaton 9155 10kVA 9kW 32-Battery 3-High w/Transformer Module Tower UPS

Eaton 9155 10kVA 9kW 32-Battery 3-High w/Transformer Module Tower UPS

$15,970.00
{{option.name}}: {{selected_options[option.position]}}
{{value_obj.value}}

The Eaton 9155 UPS provides premium online backup power and scalable battery runtimes for IT and electrical engineering infrastructure in corporate, healthcare, banking and industrial applications. Packing maximum battery runtime into a very small footprint, the 9155 UPS is a complete power protection solution. The 9155 can be equipped with an integrated, customizable power distribution module that includes a maintenance bypass switch. ​ General Topology Double-conversion Catalog Number K41013000000000 Part Number K41013000000000 Color Black Rating (VA/Watts) 10000/9000   Diagnostics Full system self-test at startup UPS Bypass Automatic on overload or UPS failure Dimensions (H x W x D, inches) 47.8 x 12 x 33.7 Weight (lbs) 558 Warranty Two-year factory warranty Contents(Ships with the following items) 1 ready-to-go UPSSoftware Suite CDUser Guide Efficiency 92% with nominal linear load; 91% with nominal computer load.   Electrical Input Connection Hardwired - see manual for terminal block layout Frequency 50/60 Hz (45 to 65 Hz) Frequency Range 45 to 65 Hz Input Power Factor P.F >0.99 typical, >0.96 frequency converter Generator Compatability Yes   Electrical Output 100/200, 110/220, 120/240 Vac 180° phase displacement; 120/208, 127/220 Vac 120° phase displacement Output Receptacles (1) PDM On Utility Voltage Regulation Output voltage regulation ±1% Static; ±5% dynamic at 100% resistive load change On Battery Voltage Regulation Output voltage regulation ±1% Static; ±5% dynamic at 100% resistive load change Overload Capacity 150% for 5 sec / 125% for 1 min (online), 110% for 10 min Voltage Wave Shape (On Battery) Sine Wave Transfer Time 0 ms   Battery   Battery Management ABM technology Battery Type 9Ah, sealed, lead-acid, maintenance-free Battery Replacement Field-replaceable Start On Battery Allows start of UPS without utility input Recharge Time Internal battery: approximately 3 hours to 80% usable capacity at nominal line voltage after full load discharge External battery: no more than 10x discharge time to 90% usable capacity at nominal line voltage after full load discharge   Communications User Interface LCD Display with blue backlight LEDs (4) LEDs for notice and alarm Audible Alarms Yes Communication Ports (1) RS-232, (1) relay contact, (1) REPO, (2) environmental input Communication Slot (2) X-Slot communication bays Power Management Software Bundled Software Suite CD   Environmental & Standards Audible Noise <53dBA at 1 meter (noise less room) typical Operating Temperature 10°C to +40°C, +45°C with 7.5% derating; Batteries recommended max. +25�C Markings UL, cUL, CSA, CE and NOM-NYCE Storage Temperature -15°C to +25°C Relative Humidity 0-95%, non condensing

Show More Show Less