CONTEC CO2 Patient Monitor Vital Signs Monitor 7 Parameters CMS9200 With ETCO2+Printer

CONTEC CO2 Patient Monitor Vital Signs Monitor 7 Parameters CMS9200 With ETCO2+Printer

$899.00
{{option.name}}: {{selected_options[option.position]}}
{{value_obj.value}}

Features     Elegant appearance, clear marks, standard interface, oxygen graph, trend graph, big characters, other BED observation, which are convenient for users.     Standard parameters: ECG, RESP, NIBP, SpO2 and dual-channel TEMP. built-in printer  ,ETCO2   ,IBP,  are optional.     Fifteen languages are optional, and all operations can be finished by keys and buttons.     15'' color LCD displays patient parameter and waveform collected, and alarm, bed NO., clock, equipment state and other information provided by the monitor synchronously.     Monitoring parameters, scan speed, volume and output contents can be set optionally.     Storage of 480-hour trend data, and review of 34-second holographic waveform.     Adopt digital SpO2 technology, strong in anti-interference and anti-weak filling capability.     Calculation of drug concentration.     Built-in rechargeable battery for uninterrupted monitoring.     Print ECG, SpO2, RESP, BP and TEMP data with one-key.     Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads).     Optional functions: Moving bracket, hanging bracket, VGA output and and 12-lead. Specification    Safety classification:    Type of protection against electroshock: Class I    Degree of protection against electroshock: type CF defibrillation-proof applied part    Degree of protection against ingress of water: IPX0    Environment requirement:    Temperature:      Working: 5~40(℃)      Transport and storage: -40~+55(℃)          Humidity      Working: 30%~75%      Transport and storage: ≤95%(no coagulation)    Power supply    Power supply: AC100~240V, 50/60 (Hz)    Maximal input power: 150VA    Battery    Working time: 90 minutes    Display    Waveform: display 8-channel waveform in a screen    Color: waveform and parameter color can be set    Waveform and parameter selection: parameter and waveform need to be displayed can be selected, and waveform position also can be adjusted.    Alarm    Alarm items: technical alarm, 71 physiological alarms and 60 arrhythmia alarms.    Prompt mode: visible, audible and character alarm (3 alarm levels)    Trend review    Time: trend review for 480-hour, review for 2400 groups of BP data    Review mode: trend graph and trend table    SD card review: trend review and review for 72-hour ECG waveform    Network    Network mode: wired, WIFI, 3G    Connection contents: connect to central monitor system by LAN or WAN; View bed    Updating mode    Software updating: network updating and U disk updating    ECG    Lead mode: 3-lead or 5-lead    Lead selection: I, II, III, aVR, aVF, aVL, V    Gain: ×0.25, ×0.5, ×1, ×2    Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s    HR:      Measurement and alarm range              Adult: 15~300bpm              Pediatric and neonatal: 15~350bpm      Accuracy: ±1% or ±1bpm, whichever is greater    ST segment monitoring:      Measurement and alarm range: -2.0mV~+2.0mV      Accuracy: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is greater    Other range: unspecified    Arrhythmia analysis: 13-arrhythmia    Volume: 0~7    Pacemaker: yes    RESPIRATION    Method: R-F(RA-LL) Impedance    Check range for respiration impedance: 0.3~5Ω    Measurement and alarm range for RESP rate: 0~120rpm    Accuracy: ±2 rpm    Apnea alarm: 10~40s    Scan speed: 6.25mm/s, 12.5mm/s, 25 mm/s    NIBP   Method: Oscillometry    Measurement and alarm range:      Adult        Systolic: 40~270mmHg        Diastolic: 10~215 mmHg        Mean: 20~235 mmHg      Pediatric        Systolic: 40~200mmHg        Diastolic: 10~150 mmHg        Mean: 20~165 mmHg      Neonate        Systolic: 40~135 mmHg        Diastolic: 10~100 mmHg        Mean: 20~110 mmHg    Inflation time: <30s(10~270 mmHg, standard adult cuff)    Measurement time: <40s    Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90 minutes    Accuracy for BP measurement: ±5mmHg, maximal standard deviation: 8mmHg    Over-pressure Protection:            Adult Mode: 297±3 mmHg            Pediatric Mode: 240±3 mmHg            Neonatal Mode: 147±3 mmHg    TEMP   Channel: dual-channel    Measurement Range: 0 ~ 50℃    Accuracy: 0.1℃    Display resolution: 0.1℃    Updating time: about 1s    SpO2    Measurement Range: 0 ~ 100 %    Measurement accuracy :70%~100%: ±2%;                                           0%~69%: unspecified    Display resolution: 1%    Upper and lower limit for alarm: 0~100%    Measurement and alarm range for PR: 0~250bpm    Measurement accuracy for PR: ±2bpm or ±2%, whichever is greater.    Pulse modulation volume: yes    Printer    Waveform: 2-channel    Print width: 48mm    Paper speed: 25mm/s, 50mm/s    EtCO2      Method: Sidestream or Mainstream    Measurement Range for CO2: 0~150mmHg    Resolution for CO2:            0.1 mm Hg: 0 to 69 mm Hg            0.25 mm Hg: 70 to 150 mm Hg    Accuracy for CO2:             0 – 40 mm Hg: ±2 mm Hg            41 – 70 mm Hg :±5%            71 – 100 mm Hg :±8%            101 – 150 mm Hg :±10%             Respiration Rate>80BPM: ±12%    AwRR Range: 0~150 rpm    Apnea Alarm: yes  Physical characteristicDimension: 363 x 168 x 339 (mm)(L×W×H)Weight: 4.9kgAccessories     User Manual     Adult fingertip SpO2 probe (5-pin)     NIBP extension tube     NIBP metal plugs     Adult NIBP cuff     ECG lead wire(American standard)     ECG electrode     Temperature probe     Power cord

Show More Show Less