CONTEC CO2 Patient Monitor Vital Signs Monitor 7 Parameters CMS9200 With ETCO2+Printer
Features Elegant appearance, clear marks, standard interface, oxygen graph, trend graph, big characters, other BED observation, which are convenient for users. Standard parameters: ECG, RESP, NIBP, SpO2 and dual-channel TEMP. built-in printer ,ETCO2 ,IBP, are optional. Fifteen languages are optional, and all operations can be finished by keys and buttons. 15'' color LCD displays patient parameter and waveform collected, and alarm, bed NO., clock, equipment state and other information provided by the monitor synchronously. Monitoring parameters, scan speed, volume and output contents can be set optionally. Storage of 480-hour trend data, and review of 34-second holographic waveform. Adopt digital SpO2 technology, strong in anti-interference and anti-weak filling capability. Calculation of drug concentration. Built-in rechargeable battery for uninterrupted monitoring. Print ECG, SpO2, RESP, BP and TEMP data with one-key. Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads). Optional functions: Moving bracket, hanging bracket, VGA output and and 12-lead. Specification Safety classification: Type of protection against electroshock: Class I Degree of protection against electroshock: type CF defibrillation-proof applied part Degree of protection against ingress of water: IPX0 Environment requirement: Temperature: Working: 5~40(℃) Transport and storage: -40~+55(℃) Humidity Working: 30%~75% Transport and storage: ≤95%(no coagulation) Power supply Power supply: AC100~240V, 50/60 (Hz) Maximal input power: 150VA Battery Working time: 90 minutes Display Waveform: display 8-channel waveform in a screen Color: waveform and parameter color can be set Waveform and parameter selection: parameter and waveform need to be displayed can be selected, and waveform position also can be adjusted. Alarm Alarm items: technical alarm, 71 physiological alarms and 60 arrhythmia alarms. Prompt mode: visible, audible and character alarm (3 alarm levels) Trend review Time: trend review for 480-hour, review for 2400 groups of BP data Review mode: trend graph and trend table SD card review: trend review and review for 72-hour ECG waveform Network Network mode: wired, WIFI, 3G Connection contents: connect to central monitor system by LAN or WAN; View bed Updating mode Software updating: network updating and U disk updating ECG Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVF, aVL, V Gain: ×0.25, ×0.5, ×1, ×2 Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s HR: Measurement and alarm range Adult: 15~300bpm Pediatric and neonatal: 15~350bpm Accuracy: ±1% or ±1bpm, whichever is greater ST segment monitoring: Measurement and alarm range: -2.0mV~+2.0mV Accuracy: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is greater Other range: unspecified Arrhythmia analysis: 13-arrhythmia Volume: 0~7 Pacemaker: yes RESPIRATION Method: R-F(RA-LL) Impedance Check range for respiration impedance: 0.3~5Ω Measurement and alarm range for RESP rate: 0~120rpm Accuracy: ±2 rpm Apnea alarm: 10~40s Scan speed: 6.25mm/s, 12.5mm/s, 25 mm/s NIBP Method: Oscillometry Measurement and alarm range: Adult Systolic: 40~270mmHg Diastolic: 10~215 mmHg Mean: 20~235 mmHg Pediatric Systolic: 40~200mmHg Diastolic: 10~150 mmHg Mean: 20~165 mmHg Neonate Systolic: 40~135 mmHg Diastolic: 10~100 mmHg Mean: 20~110 mmHg Inflation time: <30s(10~270 mmHg, standard adult cuff) Measurement time: <40s Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90 minutes Accuracy for BP measurement: ±5mmHg, maximal standard deviation: 8mmHg Over-pressure Protection: Adult Mode: 297±3 mmHg Pediatric Mode: 240±3 mmHg Neonatal Mode: 147±3 mmHg TEMP Channel: dual-channel Measurement Range: 0 ~ 50℃ Accuracy: 0.1℃ Display resolution: 0.1℃ Updating time: about 1s SpO2 Measurement Range: 0 ~ 100 % Measurement accuracy :70%~100%: ±2%; 0%~69%: unspecified Display resolution: 1% Upper and lower limit for alarm: 0~100% Measurement and alarm range for PR: 0~250bpm Measurement accuracy for PR: ±2bpm or ±2%, whichever is greater. Pulse modulation volume: yes Printer Waveform: 2-channel Print width: 48mm Paper speed: 25mm/s, 50mm/s EtCO2 Method: Sidestream or Mainstream Measurement Range for CO2: 0~150mmHg Resolution for CO2: 0.1 mm Hg: 0 to 69 mm Hg 0.25 mm Hg: 70 to 150 mm Hg Accuracy for CO2: 0 – 40 mm Hg: ±2 mm Hg 41 – 70 mm Hg :±5% 71 – 100 mm Hg :±8% 101 – 150 mm Hg :±10% Respiration Rate>80BPM: ±12% AwRR Range: 0~150 rpm Apnea Alarm: yes Physical characteristicDimension: 363 x 168 x 339 (mm)(L×W×H)Weight: 4.9kgAccessories User Manual Adult fingertip SpO2 probe (5-pin) NIBP extension tube NIBP metal plugs Adult NIBP cuff ECG lead wire(American standard) ECG electrode Temperature probe Power cord