Carbon Monoxide Combustible Fixed Gas Detector (0-150ppm)
The Fixed Combustible Carbon Monoxide (CO) Gas Detector (PX2-1-2-E1110-C-01): is designed for continuous monitoring of carbon dioxide gases to prevent leaks in the range of 0 to 150ppm for 24 hours in the confined space or automotive industries. This detector is also compatible with a wide range of controlled BMS systems and alarms, is based with a 4-20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect toxic gases. This solution is ideal for those industries using toxic gases such as car parks, automotive, refrigeration, chemical processing, and industrial manufacturing applications. Features Modular industrial design, protection class IP66 Ex db: Ignition protection for zone 1 and 2 Ex nR: Ignition protection for zone 2 Fast and Precise CO Measurements 0-150ppm Compatible across a broad range of BMS Device can be used independent of control systems Individual configuration options available Robust against dust, humidity, and high/low temperatures Suitable for multiple industries and applications Certifications ATEX and IECEx certificates MSR-Electronic GmbH for electrical Ex protection SIL2 safety functions 4–20 mA, RS-485 and relay PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” protection flame-proof enclosure PX2-2 for zone 2 Type “Ex nR” protection Enclosure: Additional FM and CSA certificates for Class I, Div. 1 Models PX2-1-2-E1130-E-01 - Gaslab Fixed Combustible Nitrogen Dioxide Detector PX2-1-2-E1125-A-01 - Gaslab Fixed Combustible Ammonia Detector PX2-1-2-E1195-A5-01 - Gaslab Fixed Combustible Oxygen Detector PX2-1-2-E1197-B-01 - Gaslab Fixed Combustible Hydrogen Sulfide Detector PX2-1-2-I464-C-01 - Gaslab Fixed Combustible Carbon Dioxide Detector PX2-1-2-P3400-A-01 - Gaslab Fixed Combustible Methane Detector PX2-1-2-P3480-A-01 - Gaslab Fixed Combustible Propane Detector Warranty 1-year warranty - see CO2Meter Terms & Conditions Specifications Gas Type: Carbon Monoxide Range ppm: 0-150ppm Admissible Range for Calibration Zero PPM: ± 10 % of measuring range Admissible Range for Calibration Gain Test Gas: 30–120 % of test gas5 Temperature Range: -30 to +50°C Storage Temperature Range: 0–20°C Humidity Range: 15-90 %RH Pressure Range: 80–120 kPa Reaction Time: ≤ 10 sec. Run-in time2: 24 h Flow Rate: 500 ml/min Warm-up Time: 300 Sec. Response Time: ≤ 200 Sec. Life-time: >15 Years Documents Data Sheet (pdf) Manual (pdf)