FLUKE 15B+ Digital multimeter Tester

FLUKE 15B+ Digital multimeter Tester

$109.90
{{option.name}}: {{selected_options[option.position]}}
{{value_obj.value}}

Feature:   LED backlight (new) Larger screen: 1.5 times of F15B's (new) Faster response time than F15B (new) Date Hold FunctionBoth Auto range and Manual range SelectableOver range protection for all rangesPolarity Indication: Indicates negative polarityOverflow IndicationSleep Mode /Auto Power off / Low Battery Indication Continuity Test with AlertDiode TestPower Supply: 2 x AA 1.5V Battery    General Specifications: Maximum Voltage between any Terminal and Earth Ground: 1000 V Display(LCD)......................................................4000 counts,updates 3/sec Battery Type......................................................2 AA,NEDA 15A, IEC LR6 Battery life........................................................500 hours minimum(50 hours in LED Test mode without load. The hours with load depends on the type of LED under test)   Temperatuer Operating..........................................................0 deg to 40 deg Storage.............................................................-30 deg to 60 deg Relative Humidity Operating Humidity..............................................Non-condensing≤90%at 10deg to 30deg;≤75% at 30deg to 40deg Operating Humidity,40MC Range..............................≤80% at 10deg to 30deg;≤70% at 30deg to 40deg Altitude Operating..........................................................2000m Storage.............................................................12.000m Temperature Coefficient.........................................0.1×(specified accuracy)/deg(<18deg or > 28deg) Fuse protection for current inputs..............................440 mA,1000 V Fast Fuse, Fluck specified part only.                                                                                         11A,1000v Fast Fuse, Fluke specified part only. Size(H×W×L).......................................................183×91×49.5(mm) Weight..............................................................455g IP Rating............................................................IP 40 Safety...............................................................IEC 61010-1, IEC61010-2-030 600V CAT Ⅲ,1000V CATⅡ,Pollution Degree 2 Electromagnetic Environment....................................IEC 61326-1:Portable Electromagnetic Compatibility...................................Applies to use in Korea only                                                                                        Class A Equipment(Industrial Broadcasting and Communication Equipment)   ACCURACY SPECIFICATION Accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])   Function Range Resolution Accuracy Model 15B+ Model 17B+ AC Volts (40 to 500 Hz) 400.0 mV 1 0.1 mV 3.0 % + 3 3.0 % + 3 4.000 V 40.00 V 400.0 V 1000 V 0.001 V 0.01 V 0.1 V 1 V 1.0 % + 3 1.0 % + 3 DC Millivolts M 400.0 mV 0.1 mV 1.0 % + 10 1.0 % + 10 DC Volts V 4.000 V 40.00 V 400.0 V 1000 V 0.001 V 0.01 V 0.1 V 1 V 0.5 % + 3 0.5 % + 3 Diode Test 2.000 V 0.001 V 10 % Temperature 50 °C to 400 °C 0 °C to 50 °C -55 °C to 0 °C 0.1 °C NA 2 % + 1 °C ± 2 °C 9 % + 2 °C Resistance (Ohms) 400.0 Ω4.000 kΩ40.00 kΩ400.0 kΩ4.000 MΩ40.00 MΩ 0.1 Ω0.001 kΩ0.01 kΩ0.1 kΩ0.001 MΩ0.01 MΩ 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 Capacitance 50.00 nF 500.0 nF 5.000 µF 50.00 µF 100.0 µF 1000.0µF 0.01 nF 0.1 nF 0.001 µF 0.01 µF 0.1 µF 1µF 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 Frequency Hz (10 Hz -100 kHz) 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz NA 0.1 % + 3 Duty Cycle 0.1 % to 99.9 % 0.1% NA 1% typical       Function Range Resolution Accuracy Model 15B+ Model 17B+ AC Current (40 to 200 Hz) 400.0 µA 0.1 µA 1.5 % + 3 1.5 % + 3   4000 µA 1 µA     AC Current (40 to 200 Hz) 40.00 mA 0.01 mA 1.5 % + 3 1.5 % + 3   400.0 mA 0.1 mA     AC Current (40 to 200 Hz) 4.000 A 10.00 A 0.001 A 0.01 A 1.5 % + 3 1.5 % + 3 DC Current 400.0 µA 0.1 µA 1.5 % + 3 1.5 % + 3   4000 µA 1 µA     DC Current 40.00 mA 0.01 mA 1.5 % + 3 1.5 % + 3 400.0 mA 0.1 mA DC Current 4.000 A 0.001 A 1.5 % + 3 1.5 % + 3   10.00 A 0.01 A         Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection AC Volts V 1000 V >10 MΩ <100 pF >60 dB at dc, 50 or 60 Hz _ DC Volts V 1000 V >10 MΩ <100 pF >100 dB at dc, 50 or 60 Hz >60 dB at 50 or 60 Hz             STANDARD ACCESSORIES 1. A Pair of Original Test leads 2. True FLUKE F15B+ meter 3. Free black carrying bag  4. Original User Manual   Note:   Now China Fluke manufacturers don't provide printed English user manual.  You can download English user manual on FLUKE website.

Show More Show Less

Price History

$109.90 ($0)
$109.90 ($0)
$109.90 ($0)